5" Pitless Booster

5 in pitless booster station Click the image to view full size
 
  • Features
  • Specifications
  • Parts Breakdown
  • Ordering Instructions

EASY ACCESS TO SERVICE... Well cap can be removed without disconnecting cables. O-ring seals on spool permit withdrawal of the entire inner assembly simply by lifting. Replacement is equally simple. Spool support eliminates vertical adjustment allowing service above ground.

CORROSION PROTECTION... Spool and Discharge Body are either lead free hot-dipped galvanized or constructed of corrosion resistant material for longer life, less service.

RELIABLE SEAL... Neoprene O-rings between accurately machined lead free hot-dipped galvanized surfaces on the spool and within the unit provide positive seals to ensure maintenance free performance.

O-RING SEAL PROTECTION... Monitor seal protection prevents seal damage during installation and service eliminating potential service costs.

QUICK TO INSTALL... A quality booster pump installation can be made easily and economically without delay for masonry or building construction creating a sound cost savings solution.

ALTERNATIVE SPOOLS (6x7 and 8x10 only)... Spools are available plain or with silent check valves. The Monitor silent check valve has its operating parts automatically exposed when the spool is withdrawn. Spools are supplied with tappings for pressure controls.

WATERTIGHT WELL CAP... Designed to permit removal without disconnecting cables. Watertight cable and conduit sealing is available for additional protection.

HOLD DOWN... Supplied with each unit. Hold-down pipe also serves as lift-out pipe for installation and allowing speedy service.

FROST PROOF... No heating is required. All water passages are below the frost line.

ALTERNATIVE DISCHARGE & INLET CONNECTIONS... Are available to meet your requirements.

5" Pitless Booster
A Seal Cap: The Watertight cap bolts to a compression seal ring securing around the
pitless case and comes with the screened well vent installed.
 
B Conduit Tapping size:
Watertight conduit seals for most common cable sizes are available for watertight cap.
1-1/2” NPT
C Distance from ground level to top of Pitless Case 12"
D Distance from ground level to top of Well Cap 14-3/4"
E Pitless Case size 6"
F Pitless Case wall thickness 280"
G "Hold Down-Lift Out Assembly": positions & clamps spool to Discharge Body to prevent rotation during pump start up Hold-Down, Lift-Out Pipe size 1-1/4"
  Designed "Lift-Out" assebmly load 4700 lbs
H Discharge body size 8-3/4" O.D. x 8-15/16" long
I Pitless Unit minimum I.D. 6"
  DISCHARGE CONNECTIONS AND SIZES  
J For Flanged (ASA Std. 150 lbs.): 2” I.D.
K For Threaded Nipple (NPT): 2” I.D.
L For Butt Weld (IPS): 2" I.D.
M For Transition Sleeve (IPS): 2" I.D.
N Dimension from center of Booster Unit to end of discharge outlet.  
  With J Flanged Discharge 9-1/4"
  With K Threded Discharge 4-7/16"
  With L Welded Discharge 6-3/4"
  With M Transition Disharge 15-3/4"
  INLET CONNECTIONS AND SIZES  
O For Flanged (ASA Std. 150 lbs): 2" I.D.
P For Threaded Nipple (NPT): 2" I.D.
Q  For Butt Weld (IPS): 2" I.D.
R For Transition Sleeve (IPS): 2” I.D.
S Dimension from center Of Booster Unit to end of Inlet Connection.  
  With O Flanged Inlet: 10-21/32"
  With P Threaded Inlet 11-5/32"
  With Q Welded Inlet 8-5/32"
  With R Transition Inlet 20-5/32"
T Discharge Body to tank pipe connection:  
U SPOOL ASSEMBLY 4200 lbs.
  Spool design load:  
V Motor Cable tapings through spool (w/cable connectors): (4) 3/8" NPT
  Maximum allowable (4) 3/8" NPT
W Tapping into Pressure Zone: 3/8" NPT
  (Furnished with square head plug)  
X Tapping into Suction Zone: 1"
  (Furnished with square head plug)  
Y Spool to drop pipe nipple connection: 2" NPT
Z Tank Pipe Size: 5" I.D.

 

Specifications are Subject to Change Without Notice.

COMPONENT MATERIALS
Cap & Conduit Box  - cast iron, green enamel finish.
Combination Hold-Down & Lift Out Mechanism - lead-free galvanized.
Hold-down pipe - steel, corrosion resistant coating
Discharge Body -steel, lead-free galvanized.
Pitless Case - steel, black corrosion resistant coating
Spool - cast iron, lead-free galvanized.
Conduit Seal & O-Rings - Neoprene

Note:- Inlet pipe & tank pipe tested to 200 P.S.I., spool disharge pressure tested to 300 P.S.I.

 

5" Pitless Booster Parts Breakdown  

Key No.
Quanity
Description
Order No.
   
1
1
Pipe Plug, 1 1/4" NPT
HD71G
2
5
Machine Bolt 3/8-16NCx3 1/2"L
PS94S
3
1
Machine Bolt 3/8-16NCx2 1/2"L
PS93S
4
1
Seal Cap
PS136
5
1
Gasket
PS196
6
2
Machine bolt, 5/16-18NCx2"L
PS132S
7
1
Retainer Ring
PS376
8
6
Hex nut 3/8-16NC
UB17S 
8A
2
Hex nut 5/16-18NC
PC434S
9
1
Seal Ring
PS166
10
1
Depression ring
PS186
11
2
Hex Nut 5/8-11NC
NA75
12
2
Washer
WA75
13
2
Hold-down Hook
UJ7BH
14
1
Lift-Out Pipe & Bail Assembly  NOTE:  Must be ordered by description and unit Serial Number
14
1
Lift-Out Pipe and Hold Down Assy     NOTE:  Must be ordered by Description & unit Serial Number
17
4
Cable Connectors     Note:  Must br ordered by description & unit Serial Number
18
2
Pipe Plug 3/8-18 NPT
UN122
25
4
Coupling 3/8-18NPT
PS182
26
4
Nipple 3/8x2-1/2 NPT
N3
33
2
O-ring
NC15
34 1 Pipe Nipple 2" NPT x 4"L PS265
35 1 Spool YC321
--- 1 Spool Assy less check valves     Includes key nos 18, 25, 26, 33, 35 & 39 6S4PSF
36 1 Casing -----
37 1 Discharge Body, FIP discharge outlet standard.  NOTE:  Must be ordered by description & unit Serial Number UE44
38 1 Tank &Inlet Pipe Assy  NOTE:  Must be ordered by description & unit Serial Number -----
39 1 Spool Plug YC218
40 8 5/8" Washer PC286
41
4
5/8" Washer
PC417
 
 
 
5" Pitless Booster
DESCRIPTION - ORDERING NUMBERS
A
6
Bury Depth in Feet
 
PS
Pitless Booster for Submersible Pump
B
5
spacerReservoir Tank Size - Ins.
C
6
spacerUpper Case Size - Ins.
D
T
spacerThreaded Joint
E
B
spacerBlack Upper Case
F
W
spacerWatertight Cap
G
X
spacerMotor Cable Passages - Sealed
  0  Check Valves
H
2
 Size of Drop Pipe in Ins. (2" std)
I
  spacerThreaded NPT Std. spacer
spacerConnection
Discharge
Connections
(Select One)
F
spacerFlange, ASA 150#
  spacerWelded
  spacerMech. Joint w/transition
spacersleeve
J
2
spacerSize of Discharge Pipe - Ins. (2" std)
K
6
spacerLength of Reservoir Tank - Feet
L 2  Inlet Pipe Size - Ins. (2" std)
M    Welded
 F  Flange, ASA 150#
 

 Threaded NPT

   Mech. Joint w/ trans. sleeve
N     
S       

Elec. Cable Seal(s)

O.D. 3 Wire_______     O.D. Ground Wire_______

   
   

Special Provision (X)

 

 

 

UNITS AVAILABLE BY QUOTATION ONLY
5” THROUGH 36” TANK SIZES

EXPLANATION OF PITLESS BOOSTER UNIT
ORDERING NUMBERS

The diagram illustrates the meaning of the various letters and numerals used in Monitor Pitless Booster Unit ordering numbers. A typical order number and the pitless unit it stands for are shown.

Typical Order Number
6PS56TBWX02F262FS

6

A. The first numeral in the order number indicates the bury depth, in feet, of the unit. Bury depth on all units is measured from the center of the discharge line to ground level. The top of the pitless case extends 12” above ground level as is required by many codes.

PS
These letters indicate the type of pump the pitless unit is designed for. The unit shown is a PS for submersible pumps.
5
B. This numeral indicates the reservoir tank size, 5 is for a 5" I.D. diameter tank.
6
C. This numeral indicates the upper pitless case size, 6 is for a 6" diameter case.
T
D. Indicates the attachment to the reservoir tank is threaded.
B
E. The presence of the letter "B" in the order nubmer indicates tha upper pitless case is black pipe.
W
F. Indicates the unit has a watertight cap.
X
G. Indicates the spool passages are closed.
0
This numeral indicates the type of spool which the pitless unit has.  In this case it is a spool that has no check valves.
2
H. Indicates the size of drop pipe in inches.
F
I. Indicates the discharge connection is Flanged.
2
J. Indicates the size of discharge pipe in inches.
6
K. Indicates the length of the reservoir tank in feet, and is measured from the center of the discharge line to the bottom of the unit.
2 L. Indicates the inlet connection diamter in inches.
F M. Indicates the inlet pipe connection is flanged.
S N. Sealed conduit connection (Optional)