The unique spool valve design and simple construction of the Monitor Magnum hydrant provides dependable operation and easy servicing in any weather. The Balanced Valve allows smooth, easy flow adjustment, since the water flow does not oppose valve movement, as in other hydrants. Corrosion resistant brass valve body, acetal spool and 1" Sch. 80 PVC wet pipe contain the water flow, extending hydrant life. The elimination of a packing nut, valve rod and linkage adjustment eliminates most of the maintenance and repair kits required with ordinary hydrants. When properly installed, occasional easy replacement of the three standard O-rings should be the only normal maintenance required.
All internal parts can be quickly removed without using pipe wrenches or digging. Turn off the water supply. Loosen the stainless steel hex screw in the collar. Pull out the inside wet pipe. Replace the o-ring. Bottom out the head casting on the stand pipe. Rotate the head casting outlet to the direction the homeowner wants and tighten the set screw. Location of outlet is approximately 24" above ground in addition to bury depth.
Contact Us about Yard Hydrants by Clicking Here
|